Avoid These 3 Common Hearing Aid Cleaning Mistakes

Properly cleaning your hearing aids is essential for their performance and longevity. However, many people unknowingly make simple mistakes that can lead to muffled sound, feedback, or even permanent damage. This guide will walk you through the three most common cleaning errors and show you the right way to care for your investment.

Mistake 1: Using Water or Harsh Chemicals

It might seem logical to use water or a standard household cleaner to get your hearing aids spotless, but this is one of the most damaging things you can do. Hearing aids are sophisticated electronic devices that are highly vulnerable to moisture and corrosive substances.

Why It’s a Problem:

  • Electronic Damage: Water can easily seep into the microphone ports, receiver opening, or battery compartment, causing short circuits and corroding the delicate internal components.
  • Casing Degradation: Rubbing alcohol, hydrogen peroxide, and other chemical solvents can break down the plastic casing of the hearing aid, making it brittle and prone to cracking. They can also strip away protective coatings.
  • Blocked Microphones: Using cleaning sprays or liquids can push debris deeper into the microphone ports instead of removing it, leading to a significant decrease in sound quality.

The Correct Method: Your primary tool for daily cleaning should always be a soft, dry cloth. Microfiber cloths, like those used for cleaning eyeglasses, are perfect for this task. Gently wipe the entire surface of the hearing aid to remove any oils or debris that have accumulated throughout the day.

For more stubborn buildup, especially around microphone ports and seams, use the small, soft brush that likely came with your hearing aids. If you’ve lost it, you can purchase a dedicated hearing aid cleaning tool kit online or from your audiologist. These kits often include a brush, a wax pick or loop, and a vent cleaner. Never use water or any liquid that is not specifically labeled as safe for hearing aids.

Mistake 2: Only Wiping the Outside Shell

A quick wipe of the hearing aid body is a good start, but it’s not enough. Earwax and debris naturally build up in the small openings of the device, which are critical for its function. Neglecting these areas is a fast track to poor performance.

Why It’s a Problem:

  • Muffled Sound: The most common cause of a hearing aid sounding weak or muffled is a blocked receiver (the speaker) or a clogged wax guard. If sound cannot get out, the device is useless.
  • Feedback and Whistling: Debris blocking a vent can cause sound to bounce back into the microphone, creating annoying feedback.
  • Damage to Components: When earwax is left to build up, it can work its way into the receiver, causing permanent damage that requires a costly professional repair.

The Correct Method for Key Components:

Your cleaning routine should address all parts of your specific hearing aid style.

For Behind-the-Ear (BTE) Models:

  • Earmold and Tubing: Detach the custom earmold and tubing from the hearing aid body. You can wash the earmold and tubing with mild soap and warm water, but you must ensure it is completely dry before reattaching it. Use a hearing aid air blower (a small puffer tool) to force all moisture out of the tubing.
  • Hearing Aid Body: Never submerge the main electronic component. Clean it with your dry cloth and brush, paying close attention to the microphone ports.

For In-the-Ear (ITE) and Receiver-in-Canal (RIC) Models:

  • Microphone Ports: Use your soft brush to gently clear away any debris from the small holes where sound enters the hearing aid. Angle the hearing aid downwards so that the debris falls out, not in.
  • Receiver Opening and Wax Guards: The opening where the sound comes out is protected by a tiny white filter called a wax guard. These are designed to be replaced regularly. If the sound is weak, your wax guard is likely clogged. Most hearing aid brands, like Phonak or Starkey, have their own specific wax guard systems (e.g., CeruStop, Hear Clear). Follow the manufacturer’s instructions to remove the old filter and insert a new one. This simple step can instantly restore sound quality.

Mistake 3: Improper Drying and Storage

Your cleaning routine isn’t finished until your hearing aids are stored correctly. Tossing them onto a nightstand or leaving them in a humid bathroom exposes them to moisture and potential physical damage.

Why It’s a Problem:

  • Moisture Buildup: Even if you don’t expose them directly to water, humidity and perspiration can accumulate inside the hearing aids. This moisture can corrode the battery contacts and damage the internal circuitry over time.
  • Battery Drain: Leaving the battery door closed when not in use can cause a slow drain on the battery, shortening its life. For rechargeable models, improper storage can affect long-term battery health.
  • Physical Damage: Leaving hearing aids out in the open makes them vulnerable to being knocked on the floor, chewed by pets, or misplaced.

The Correct Method: At the end of each day, create a habit of proper storage.

  1. Open the Battery Door: After wiping down your hearing aids, open the battery compartment fully. This deactivates the device, saving battery life, and allows air to circulate overnight, helping to evaporate any moisture that has built up.
  2. Use a Dehumidifier: The best way to protect your hearing aids from moisture is to store them in a dedicated hearing aid dryer or dehumidifier.
    • Desiccant Jars: These are simple, non-electric options. You place your hearing aids (with battery doors open) into a jar containing a desiccant puck (like the one in a Stay Dri Dehumidifier Jar) that absorbs moisture. The puck can be reactivated in the microwave.
    • Electronic Dryers: For a more advanced solution, an electronic drying station (like the PerfectDry Lux) uses gentle heat to remove moisture and often includes a UV-C light cycle to sanitize the hearing aids, killing bacteria and germs.

By avoiding these three common mistakes and adopting a consistent, gentle cleaning routine, you will ensure your hearing aids function at their best and last for years to come.

Frequently Asked Questions

How often should I clean my hearing aids? You should perform a quick cleaning every day. This involves wiping the device with a soft, dry cloth. A more thorough cleaning, including brushing the microphone ports and checking the wax guard, should be done at least once a week or more often if you produce a lot of earwax.

Can I use a pre-moistened wipe? You should only use wipes that are specifically manufactured and sold for cleaning hearing aids. Standard antibacterial or baby wipes contain chemicals and levels of moisture that can damage the sensitive electronics and coatings on your devices.

What should I do if my hearing aid accidentally gets wet? First, do not panic. Immediately remove the battery. Gently pat the outside of the hearing aid dry with a soft cloth. Do not use a hairdryer or microwave, as high heat will destroy the device. Place the hearing aid with the battery door open in a hearing aid dehumidifier for at least 8-10 hours before trying a new battery. If it still doesn’t work, contact your audiologist.